MXM155

Service: Electrical > Error code 7

Problem

Error code 7

Solution

1. Replace the coolant temperature sender. If error code 7 is still being displayed, continue to step 2.

2. Check for a short circuit.
– Disconnect connector C012 and the instrument cluster C079. Measure the resistance between connector C079 pin 1 (G/U) and C079 pin 2 (B). If the resistance indicated is less than 5000 Ohms, repair or replace the harness as required.
– If the resistance indicated is more than 5000 Ohms, remove and replace the instrument cluster.